BMW 7 Owners & Service Manuals
BMW 7 Series (F01/F02) 2008-2015 Service Manual / General Electrical System / Troubleshooting / Instructions For Opening Contacts And Locks Of Different Plug Contact Systems

BMW 7 Series: Instructions For Opening Contacts And Locks Of Different Plug Contact Systems

Notes

SPECIAL TOOLS DESCRIPTION CHART

Troubleshooting

Troubleshooting

IMPORTANT: The contacts can be changed on ultrasonically welded plugs (1).

Ultrasonically welded plugs (1) must be replaced completely.

Ultrasonic-welded connectors (1) can be identified by the welds (2) on their longitudinal side.

Troubleshooting
Fig. 3: Identifying Ultrasonic-Welded Connectors With Welds

NOTE: Special tools referred to in the repair instructions below are contained in the following special tool kits:

  • Release and pressing-off tool 61 1 150
    will be replaced on 09/2005 by 61 0 300 (BMW) and 61 0 400 (MINI)
  • Release and pressing-off tool 61 1 100 (engine)

Repair instructions for opening plug housings and removing contacts of different plug systems

Plug system D 1.5/D 2.5

  • CIRCULAR PLUGS, 7-, 8-PIN, SYSTEM D2.5
  • CIRCULAR CONNECTOR, 13-PIN, SYSTEM D2.5
  • CIRCULAR CONNECTOR, 20-PIN, SYSTEM D2.5
  • CIRCULAR CONNECTORS, 4-, 7-, 10- 12-, 25-PIN, SYSTEM D1.5/D2.5
  • INLINE CONNECTORS, 15-PIN, SYSTEM D2.5
  • INLINE PLUGS, 8-, 12-PIN, SYSTEM D2.5
  • IN-LINE CONNECTORS, 30-PIN, SYSTEM D2.5
  • IN-LINE PLUGS, 20-PIN, SYSTEM D2.5

Plug system JPT/MDK/DFK

  • IN-LINE PLUGS, 2-PIN, SYSTEM JPT ELA
  • IN-LINE CONNECTORS, 2-PIN, SYSTEM MDK 3PLUS 2.8
  • IN-LINE PLUGS, 4-PIN, SYSTEM DFK ELA

Plug system Elo/Elo Power

  • INLINE PLUGS, 4-, 10-PIN, SYSTEM ELO
  • IN-LINE PLUGS, 6- TO 50-PIN, SYSTEM ELO
  • IN-LINE CONNECTORS, 3-, 6-PIN, SYSTEM ELO-POWER 2.8

Plug system LSK

  • CONNECTOR HOUSING, LCC CONTACT (LOAD CURRENT CONTACT)

Plug system MQS/MPQ

  • INLINE CONNECTORS, 6-, 8-PIN, SYSTEM MQS
  • INLINE PLUGS, 2-PIN, SYSTEM MPQ 2.8
  • CONTROL UNIT CONNECTORS, 25-, 35-, 55-, 83-, 88-PIN
  • IN-LINE PLUGS, 24-PIN, HYBRID SYSTEM MQS/MPQ
  • SOCKET HOUSING 42-, 43-PIN, HYBRID SYSTEM MQS/MPQ
  • SOCKET HOUSINGS, 2X21-, 2X27-PIN, HYBRID SYSTEMS MQS/MPQ, ELO/ELO POWER
  • IN-LINE CONNECTORS, 30-PIN, HYBRID SYSTEM MQS/MPQ
  • SOCKET HOUSINGS, 5-PIN, 8-PIN, SYSTEM MQS/MPQ
  • SOCKET HOUSING (RADIO CONNECTOR), HYBRID SYSTEM MQS/MPQ

    READ NEXT:

     Notes On Handling Optical Fibres

    IMPORTANT: To avoid damage when handling optical fibres, comply with the following points: The minimum permitted bending radius is 25 mm Do not subject optical fibres to compressive and tensile lo

     Repairing Airbag Cables

    IMPORTANT: Only repair those cables which show visible signs of damage. In the event of visible damage, make sure there is only one cable repair in effect after the repair work. If no visible damage

     Wiring Harness

    SEE MORE:

     Operating Fluids

    1.0 GENERAL INFORMATION ON FINAL DRIVE OIL Final Drive oil or hypoid gear lubricant must conform with the following requirements because of the high loads which occur on the profiles of the hypoid gear teeth: Load carrying capacity. Sufficient protection against seizure. Good wear protection.

     Introduction

    The front seating arrangement of the F01/F02 consists of the multi-function seat as standard equipment. The multi-function seat (Comfort Seat) features 16-way adjustment with 4-way lumbar support which includes the articulated upper backrest, adjustable backrest width, adjustable thigh support, a

    © 2019-2026 Copyright www.bmw7g11.com