Notes
Set pressure regulator on special tool 16 1 171 fully in "-" direction.
Connect special tool 16 1 171 using compressed air line (1) to workshop
compressed air system (8... 10 bar).
Connect pre
Recycling
Fuel escapes when fuel lines are detached. Have a suitable collecting
container ready.
Catch and dispose of escaping fuel.
Observe country-specific waste-disposal regulations.
IMPORTANT:
Recycling
Fuel escapes when fuel lines are detached. Have a suitable collecting
container ready.
Catch and dispose of escaping fuel.
Observe country-specific waste-disposal regulations.
IMPORTANT:
REMOVING AND INSTALLING (REPLACING) TELEMATIC COMMUNICATION BOX
IMPORTANT: Read and comply with notes on protection against electrical
damage (ESD
PROTECTION).
Comply with notes and instructions on HANDLING OPTICAL FIBRES.
Necessary preliminary work:
Clamp off BATTERY NEGATIVE LEAD.
Remove LEFT
Park Distance Control
The Park Distance Control of the F01/F02 is identifiable by the five
ultrasonic sensors on the front bumper. The
fifth sensor enables a high level of reliability in obstacle recognition to be
achieved despite the large front end
of the F01.
Fig. 136: F01/F02 Front Bumper Wit